Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 29.147
Filter
1.
J Cardiothorac Surg ; 19(1): 279, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38715032

ABSTRACT

OBJECTIVE: Reports on long-term outcomes of surgical aortic valve replacement (AVR) for patients aged < 60 years are scarce in Japan. Hence, we aimed to evaluate these outcomes in patients aged < 60 years. METHODS: Between March 2000 and December 2020, 1477 patients underwent aortic valve replacement. In total, 170 patients aged < 60 years who underwent aortic valve replacement were recruited. Patients aged < 18 years were excluded. Patient data collected from the operative records and follow-up assessments were reviewed. RESULTS: The mean age was 49 ± 9 years, and 64.1% of patients were male. One-hundred-and-fifty-two patients (89.4%) underwent aortic valve replacement with a mechanical valve and 18 (10.6%) with a bioprosthetic valve. The mean follow-up period was 8.1 ± 5.5 years. No operative mortality occurred, and in-hospital mortality occurred in one patient (0.6%). Ten late deaths occurred, with seven cardiac-related deaths. The overall survival rate was 95.4 ± 1.7%, 93.9 ± 2.3%, 90.6 ± 3.9%, and 73.2 ± 11.8% at 5, 10, 15, and 20 years, respectively. Freedom from major bleeding was 96.4 ± 1.6% at 5, 10, and 15 years, and 89.0 ± 7.3% at 20 years. Freedom from thromboembolic events was 98.7 ± 1.3%, 97.3 ± 1.9%, 90.5 ± 4.5%, and 79.0 ± 11.3% at 5, 10, 15, and 20 years, respectively. Freedom from valve-related reoperation was 99.4 ± 0.6% at 5 years, 97.8 ± 1.7% at 10 and 15 years, and 63.9 ± 14.5% at 20 years. CONCLUSIONS: Patients aged < 60 years undergoing aortic valve replacement with a high mechanical valve implantation rate had favorable long-term outcomes.


Subject(s)
Aortic Valve , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Humans , Male , Middle Aged , Female , Heart Valve Prosthesis Implantation/methods , Aortic Valve/surgery , Adult , Bioprosthesis , Retrospective Studies , Postoperative Complications/epidemiology , Japan/epidemiology , Follow-Up Studies , Treatment Outcome , Survival Rate/trends , Age Factors , Time Factors , Hospital Mortality
2.
Ann Card Anaesth ; 27(1): 68-69, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-38722126

ABSTRACT

ABSTRACT: The occurrence of pulmonary artery thrombus in association with rheumatic mitral stenosis is a rare complication. Pulmonary artery thrombus formation may worsen pulmonary artery pressures, and this may precipitate acute right heart failure. The possible mechanisms behind pulmonary artery thrombus formation during mitral valve replacement surgery could be acute coagulopathy following surgery, the presence of chronic pulmonary thromboembolism, or chronic atrial fibrillation. We report an unusual case of pulmonary artery thrombus in a patient with rheumatic MS which was diagnosed with transoesophageal echocardiography after MVR.


Subject(s)
Delayed Diagnosis , Echocardiography, Transesophageal , Heart Valve Prosthesis Implantation , Mitral Valve , Pulmonary Artery , Thrombosis , Humans , Heart Valve Prosthesis Implantation/adverse effects , Pulmonary Artery/diagnostic imaging , Echocardiography, Transesophageal/methods , Thrombosis/diagnostic imaging , Thrombosis/etiology , Mitral Valve/surgery , Mitral Valve/diagnostic imaging , Mitral Valve Stenosis/surgery , Female , Rheumatic Heart Disease/complications , Rheumatic Heart Disease/surgery , Pulmonary Embolism/etiology , Pulmonary Embolism/diagnostic imaging , Middle Aged
4.
Medicine (Baltimore) ; 103(19): e38022, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38728459

ABSTRACT

Warfarin, a widely utilized anticoagulant, is paramount for preventing thromboembolic events in patients with mechanical heart valve replacements. However, its narrow therapeutic index can lead to over-anticoagulation and overdose, resulting in serious health risks. This study examines the efficacy of human prothrombin complex concentrate (PCC) in managing warfarin overdose, in comparison with traditional treatments. A retrospective analysis was conducted on 162 adults who presented with warfarin overdose (INR > 5.0) at a tertiary care hospital between 2016 and 2020. Participants were divided into 2 groups-those treated with PCC (n = 57) and those treated with conventional methods (n = 105), including vitamin K and fresh frozen plasma. The primary outcome was the rate of reaching the target (International Normalized Ratio) INR within 24 hours. Secondary outcomes included transfusion requirements, thromboembolic events, adverse reactions, 30-day mortality, and length of hospital stay. PCC demonstrated significant efficacy, with 89.5% of patients achieving the target INR within 24 hours, compared to 64.8% in the control group (P < .05). The PCC group also had reduced transfusion requirements and a shorter average hospital stay. There was no significant difference in thromboembolic events or adverse reactions between the 2 groups, and the reduced 30-day mortality in the PCC group was not statistically significant. Human prothrombin complex concentrate is associated with rapid reaching the target INR, decreased transfusion needs, and shortened hospitalization, making it a promising option for warfarin overdose management. While the results are encouraging, larger, multicenter, randomized controlled trials are necessary to further validate these findings and optimize PCC administration protocols.


Subject(s)
Anticoagulants , Blood Coagulation Factors , Drug Overdose , International Normalized Ratio , Warfarin , Humans , Warfarin/adverse effects , Warfarin/therapeutic use , Blood Coagulation Factors/therapeutic use , Blood Coagulation Factors/administration & dosage , Female , Male , Retrospective Studies , Anticoagulants/adverse effects , Anticoagulants/therapeutic use , Middle Aged , Drug Overdose/drug therapy , Drug Overdose/therapy , Aged , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Thromboembolism/prevention & control , Adult , Treatment Outcome , Blood Transfusion/statistics & numerical data , Length of Stay/statistics & numerical data , Vitamin K/therapeutic use
5.
Eur J Cardiothorac Surg ; 65(5)2024 May 03.
Article in English | MEDLINE | ID: mdl-38710669

ABSTRACT

OBJECTIVES: The objective of this analysis was to assess the normal haemodynamic performance of contemporary surgical aortic valves at 1 year postimplant in patients undergoing surgical aortic valve replacement for significant valvular dysfunction. By pooling data from 4 multicentre studies, this study will contribute to a better understanding of the effectiveness of surgical aortic valve replacement procedures, aiding clinicians and researchers in making informed decisions regarding valve selection and patient management. METHODS: Echocardiograms were assessed by a single core laboratory. Effective orifice area, dimensionless velocity index, mean aortic gradient, peak aortic velocity and stroke volume were evaluated. RESULTS: The cohort included 2958 patients. Baseline age in the studies ranged from 70.1 ± 9.0 to 83.3 ± 6.4 years, and Society of Thoracic Surgeons risk of mortality was 1.9 ± 0.7 to 7.5 ± 3.4%. Twenty patients who had received a valve model implanted in fewer than 10 cases were excluded. Ten valve models (all tissue valves; n = 2938 patients) were analysed. At 1 year, population mean effective orifice area ranged from 1.46 ± 0.34 to 2.12 ± 0.59 cm2, and dimensionless velocity index, from 0.39 ± 0.07 to 0.56 ± 0.15. The mean gradient ranged from 8.6 ± 3.4 to 16.1 ± 6.2 mmHg with peak aortic velocity of 1.96 ± 0.39 to 2.65 ± 0.47 m/s. Stroke volume was 75.3 ± 19.6 to 89.8 ± 24.3 ml. CONCLUSIONS: This pooled cohort is the largest to date of contemporary surgical aortic valves with echocardiograms analysed by a single core lab. Overall haemodynamic performance at 1 year ranged from good to excellent. These data can serve as a benchmark for other studies and may be useful to evaluate the performance of bioprosthetic surgical valves over time. CLINICAL TRIAL REGISTRATION NUMBER: NCT02088554, NCT02701283, NCT01586910 and NCT01531374.


Subject(s)
Aortic Valve , Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Hemodynamics , Humans , Hemodynamics/physiology , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aged , Female , Male , Aged, 80 and over , Heart Valve Prosthesis Implantation/methods , Echocardiography , Middle Aged , Prosthesis Design
6.
Kyobu Geka ; 77(5): 361-363, 2024 May.
Article in Japanese | MEDLINE | ID: mdl-38720605

ABSTRACT

Prosthetic valve endocarditis (PVE) is rare but devastating. A 69-year old man admitted for active endocarditis caused by Streptococcus pasteurianus. Antibiotic therapy was started, but the patient developed bowel obstruction owing to cancer with multiple liver metastases, and underwent transverse colectomy. Following colectomy, antibiotic agent was given continued for 4 weeks after and mitral valve replacement( MVR) using a bioprosthesis was performed. Oral antibiotic therapy was continued for six months after MVR to avoid infection recurrence. One year after MVR, the size of multiple liver metastases increased despite oral anticancer drugs administration. A totally implantable central venous access port( CV port) was placed and intravenous chemotherapy was started for progressive metastatic colorectal cancer. But the CV port was removed due to device infection caused by multiple drug resistant Staphyrococcus lugdunensis one month later, but the patient developed prosthetic valve endocarditits( PVE) due to the same bacterium, that caused valve stenosis. Redo MVR was indicated because of progressive dyspnea and uncontrollable fever. The patient was discharged one month after redo MVR, but suffered carcinomatous peritonitis, and eventually died eight months post-discharge. Chemotherapy needs caution because of potential risk of PVE in patients with prosthetic valves, especially for those with a history of infectious endocarditis.


Subject(s)
Colonic Neoplasms , Heart Valve Prosthesis , Mitral Valve , Humans , Male , Aged , Mitral Valve/surgery , Colonic Neoplasms/surgery , Colonic Neoplasms/complications , Heart Valve Prosthesis/adverse effects , Fatal Outcome , Reoperation , Prosthesis-Related Infections/surgery , Prosthesis-Related Infections/etiology , Heart Valve Prosthesis Implantation , Endocarditis, Bacterial/surgery
7.
Open Heart ; 11(1)2024 May 20.
Article in English | MEDLINE | ID: mdl-38769066

ABSTRACT

OBJECTIVE: Patients with moderate aortic stenosis (AS) exhibit high morbidity and mortality. Limited evidence exists on the role of aortic valve replacement (AVR) in this patient population. To investigate the benefit of AVR in moderate AS on survival and left ventricular function. METHODS: In a retrospective cohort study, patients with moderate AS between 2008 and 2016 were selected from the Cleveland Clinic echocardiography database and followed until 2018. Patients were classified as receiving AVR or managed medically (clinical surveillance). All-cause and cardiovascular mortality were assessed by survival analyses. Temporal haemodynamic and structural changes were assessed with longitudinal analyses using linear mixed effects models. RESULTS: We included 1421 patients (mean age, 75.3±5.4 years and 39.9% women) followed over a median duration of 6 years. Patients in the AVR group had lower risk of all-cause (adjusted HR (aHR)=0.51, 95% CI: 0.34 to 0.77; p=0.001) and cardiovascular mortality (aHR=0.50, 95% CI: 0.31 to 0.80; p=0.004) compared with those in the clinical surveillance group irrespective of sex, receipt of other open-heart surgeries and underlying malignancy. These findings were seen only in those with preserved left ventricular ejection fraction (LVEF) ≥50%. Further, patients in the AVR group had a significant trend towards an increase in LVEF and a decrease in right ventricular systolic pressure compared with those in the clinical surveillance group. CONCLUSIONS: In patients with moderate AS, AVR was associated with favourable clinical outcomes and left ventricular remodelling.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Heart Valve Prosthesis Implantation , Ventricular Function, Left , Humans , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/diagnosis , Female , Male , Retrospective Studies , Aged , Heart Valve Prosthesis Implantation/methods , Ventricular Function, Left/physiology , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Treatment Outcome , Time Factors , Severity of Illness Index , Follow-Up Studies , Risk Factors , Echocardiography/methods , Aged, 80 and over , Survival Rate/trends , Risk Assessment/methods , Stroke Volume/physiology
9.
Eur J Cardiothorac Surg ; 65(5)2024 May 03.
Article in English | MEDLINE | ID: mdl-38730543

ABSTRACT

OBJECTIVES: The aim of this study was to describe trends and outcomes for patients undergoing surgical aortic valve replacement (SAVR) in the Netherlands. METHODS: The Netherlands Heart Registration database was used to report the number and outcomes of isolated, primary SAVR procedures performed from 2007 to 2018 in adult patients. RESULTS: A total of 17 142 procedures were included, of which 77.9% were performed using a biological prosthesis and 21.0% with a mechanical prosthesis. Median logistic EuroSCORE I decreased from 4.6 [interquartile range (IQR) 2.4-7.7] to 4.0 (IQR 2.6-6.0). The 120-day mortality decreased from 3.3% in 2007 to 0.7% in 2018. The median duration of follow-up was 76 months (IQR 53-111). Ten-year survival, when adjusted for age, EuroSCORE I and body surface area, was 72.4%, and adjusted 10-year freedom from reinvervention was 98.1%. Additional analysis for patients under the age of 60 showed no difference between patients treated with a biological or mechanical prosthesis in adjusted 10-year survival, 89.7% vs 91.9±%, respectively (P = 0.25), but a significant difference in adjusted 10-year freedom from reintervention, 90.0±% vs 95.9%, respectively (P < 0.01). CONCLUSIONS: Between 2007 and 2018, age and risk profile of patients undergoing SAVR decreased, especially for patients treated with a biological prosthesis. The 120-day mortality decreased over time. Patients undergoing SAVR nowadays have a risk of 120-day mortality of <1% and 10-year freedom from valve-related reintervention of >95%.


Subject(s)
Aortic Valve , Heart Valve Prosthesis Implantation , Humans , Male , Netherlands/epidemiology , Female , Aged , Aortic Valve/surgery , Heart Valve Prosthesis Implantation/trends , Heart Valve Prosthesis Implantation/statistics & numerical data , Heart Valve Prosthesis Implantation/mortality , Heart Valve Prosthesis Implantation/methods , Middle Aged , Treatment Outcome , Heart Valve Prosthesis/trends , Aged, 80 and over , Registries , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Risk Factors
10.
BMC Cardiovasc Disord ; 24(1): 250, 2024 May 14.
Article in English | MEDLINE | ID: mdl-38745119

ABSTRACT

OBJECTIVES: Prolonged mechanical ventilation (PMV) is a common complication following cardiac surgery linked to unfavorable patient prognosis and increased mortality. This study aimed to search for the factors associated with the occurrence of PMV after valve surgery and to develop a risk prediction model. METHODS: The patient cohort was divided into two groups based on the presence or absence of PMV post-surgery. Comprehensive preoperative and intraoperative clinical data were collected. Univariate and multivariate logistic regression analyses were employed to identify risk factors contributing to the incidence of PMV. Based on the logistic regression results, a clinical nomogram was developed. RESULTS: The study included 550 patients who underwent valve surgery, among whom 62 (11.27%) developed PMV. Multivariate logistic regression analysis revealed that age (odds ratio [OR] = 1.082, 95% confidence interval [CI] = 1.042-1.125; P < 0.000), current smokers (OR = 1.953, 95% CI = 1.007-3.787; P = 0.047), left atrial internal diameter index (OR = 1.04, 95% CI = 1.002-1.081; P = 0.041), red blood cell count (OR = 0.49, 95% CI = 0.275-0.876; P = 0.016), and aortic clamping time (OR = 1.031, 95% CI = 1.005-1.057; P < 0.017) independently influenced the occurrence of PMV. A nomogram was constructed based on these factors. In addition, a receiver operating characteristic (ROC) curve was plotted, with an area under the curve (AUC) of 0.782 and an accuracy of 0.884. CONCLUSION: Age, current smokers, left atrial diameter index, red blood cell count, and aortic clamping time are independent risk factors for PMV in patients undergoing valve surgery. Furthermore, the nomogram based on these factors demonstrates the potential for predicting the risk of PMV in patients following valve surgery.


Subject(s)
Nomograms , Predictive Value of Tests , Respiration, Artificial , Humans , Risk Factors , Male , Female , Middle Aged , Respiration, Artificial/adverse effects , Time Factors , Risk Assessment , Aged , Retrospective Studies , Treatment Outcome , Cardiac Surgical Procedures/adverse effects , Decision Support Techniques , Adult , Heart Valve Prosthesis Implantation/adverse effects , Heart Valves/surgery , Heart Valve Diseases/surgery , Age Factors
11.
Braz J Cardiovasc Surg ; 39(4): e20230154, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38748974

ABSTRACT

INTRODUCTION: It is not yet clear whether cardiac surgery by mini-incision (minimally invasive cardiac surgery [MICS]) is overall less painful than the conventional approach by full sternotomy (FS). A meta-analysis is necessary to investigate polled results on this topic. METHODS: PubMed®/MEDLINE, Cochrane CENTRAL, Latin American and Caribbean Health Sciences Literature (or LILACS), and Scientific Electronic Library Online (or SciELO) were searched for all clinical trials, reported until 2022, comparing FS with MICS in coronary artery bypass grafting (CABG), mitral valve surgery (MVS), and aortic valve replacement (AVR), and postoperative pain outcome was analyzed. Main summary measures were the method of standardized mean differences (SMD) with a 95% confidence interval (CI) and P-values (considered statistically significant when < 0.05). RESULTS: In AVR, the general estimate of postoperative pain effect favored MICS (SMD 0.87 [95% CI 0.04 to 1.71], P=0.04). However, in the sensitivity analysis, there was no difference between the groups (SMD 0.70 [95% CI -0.69 to 2.09], P=0.32). For MVS, it was not possible to perform a meta-analysis with the included studies, because they had different methodologies. In CABG, the general estimate of the effect of postoperative pain did not favor any of the approaches (SMD -0.40 [95% CI -1.07 to 0.26], P=0.23), which was confirmed by sensitivity analysis (SMD -0.02 [95% CI -0.71 to 0.67], P=0.95). CONCLUSION: MICS was not globally less painful than the FS approach. It seems that postoperative pain is more related to the degree of tissue retraction than to the size of the incision.


Subject(s)
Cardiac Surgical Procedures , Coronary Artery Bypass , Minimally Invasive Surgical Procedures , Pain, Postoperative , Sternotomy , Humans , Sternotomy/adverse effects , Sternotomy/methods , Pain, Postoperative/etiology , Cardiac Surgical Procedures/methods , Cardiac Surgical Procedures/adverse effects , Coronary Artery Bypass/adverse effects , Coronary Artery Bypass/methods , Minimally Invasive Surgical Procedures/methods , Minimally Invasive Surgical Procedures/adverse effects , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis Implantation/adverse effects
12.
Braz J Cardiovasc Surg ; 39(4): e20230237, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38748975

ABSTRACT

Transcatheter mitral valve-in-valve is an alternative to high-risk reoperation on a failing bioprosthesis. It entails specific challenges such as left ventricular outflow tract obstruction. We propose a patient-specific augmented imaging based on preoperative planning to assist the procedure. Valve-in-valve simulation was performed to represent the optimal level of implantation and the neo-left ventricular outflow tract. These data were combined with intraoperative images through a real-time 3D/2D registration tool. All data were collected retrospectively on one case (pre and per-procedure imaging). We present for the first time an intraoperative guidance tool in transcatheter mitral valve-in-valve procedure.


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve , Surgery, Computer-Assisted , Humans , Heart Valve Prosthesis Implantation/methods , Mitral Valve/surgery , Mitral Valve/diagnostic imaging , Surgery, Computer-Assisted/methods , Cardiac Catheterization/methods , Bioprosthesis , Retrospective Studies , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/diagnostic imaging , Female , Male
13.
Clin Cardiol ; 47(5): e24272, 2024 May.
Article in English | MEDLINE | ID: mdl-38742736

ABSTRACT

Paravalvular leak (PVL) is an uncommon complication of prosthetic valve implantation, which can lead to infective endocarditis, heart failure, and hemolytic anemia. Surgical reintervention of PVLs is associated with high mortality rates. Transcatheter PVL closure (TPVLc) has emerged as an alternative to surgical reoperation. This method provides a high success rate with a low rate of complications. This article reviews the pathogenesis, clinical manifestation, diagnosis, and management of PVL and complications following TPVLc. Besides, we presented a case of a patient with severe PVL following mitral valve replacement, who experienced complete heart block (CHB) during TPVLc. The first TPVLc procedure failed in our patient due to possible AV-node insult during catheterization. After 1 week of persistent CHB, a permanent pacemaker was implanted. The defect was successfully passed using the previous attempt. Considering the advantages of TPVLc, procedure failure should be regarded as a concern. TPVLc should be performed by experienced medical teams in carefully selected patients.


Subject(s)
Cardiac Catheterization , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve , Prosthesis Failure , Humans , Mitral Valve/surgery , Mitral Valve/diagnostic imaging , Cardiac Catheterization/methods , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Heart Valve Prosthesis/adverse effects , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/methods , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/etiology , Echocardiography, Transesophageal , Male , Treatment Outcome , Female , Aged , Reoperation
14.
Clin Cardiol ; 47(5): e24268, 2024 May.
Article in English | MEDLINE | ID: mdl-38741388

ABSTRACT

BACKGROUND: Observational studies suggest that valvular surgery can reduce mortality in selected patients with infective endocarditis (IE). However, the benefit of this intervention according to frailty levels remains unclear. Our study aims to assess the effect of valvular surgery according to frailty status in this population. METHODS: We performed a retrospective study using the 2016-2019 National Inpatient Sample database. Adult patients with a primary diagnosis of IE were included. Frailty was assessed using the Hospital Frailty Risk Score. Inverse probability of treatment weighting (IPTW) was used to balance baseline differences between groups. RESULTS: A total of 53,275 patients with IE were included, with 18.3% underwent valvular surgery. The median age was 52 (34-68) years, with 41% females. Overall, 42.7% had low risk of frailty, 53.1% intermediate risk, and 4.2% high risk. After IPTW adjustment, in-hospital mortality was similar both for the entire cohort between valvular and non-valvular surgery groups (3.7% vs. 4.1%, p = .483), and low (1% vs. 0.9%, p = .952) or moderate (5.4% vs. 6%, p = .548) risk of frailty. However, patients at high risk of frailty had significantly lower in-hospital mortality in the valvular surgery group (4.6% vs. 13.9%, p = .016). Renal replacement therapy was similar between groups across frailty status. In contrast, surgery was associated with increased use of mechanical circulatory support and pacemaker implantation. CONCLUSIONS: Our findings suggest that there was no difference in survival between valve surgery and medical management in patients at low/intermediate frailty risk, but not for high-risk individuals.


Subject(s)
Endocarditis , Frailty , Hospital Mortality , Humans , Female , Male , Middle Aged , Retrospective Studies , Frailty/complications , Frailty/diagnosis , Aged , Endocarditis/surgery , Endocarditis/mortality , Endocarditis/complications , Risk Factors , Risk Assessment/methods , Adult , United States/epidemiology , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Diseases/surgery , Heart Valve Diseases/complications , Survival Rate/trends
15.
J Am Heart Assoc ; 13(10): e033605, 2024 May 21.
Article in English | MEDLINE | ID: mdl-38742523

ABSTRACT

BACKGROUND: Minimally invasive mitral valve repair has a favorable risk-benefit profile in patients with significant de novo mitral regurgitation. Its role in patients with prior mitral valve repair is uncertain. We aimed to appraise the outcome of patients undergoing transcatheter edge-to-edge repair (TEER) with prior transcatheter or surgical mitral valve repair (SMVR). METHODS AND RESULTS: We queried the Italian multicenter registry on TEER with MitraClip, distinguishing naïve patients from those with prior TEER or (SMVR). Inhospital and long-term clinical/echocardiographic outcomes were appraised. The primary outcome was the occurrence of death or rehospitalization for heart failure. A total of 2238 patients were included, with 2169 (96.9%) who were naïve to any mitral intervention, 29 (1.3%) with prior TEER, and 40 (1.8%) with prior SMVR. Several significant differences were found in baseline clinical and imaging features. Respectively, device success was obtained in 2120 (97.7%), 28 (96.6%), and 38 (95.0%, P=0.261) patients; procedural success in 2080 (95.9%), 25 (86.2%), and 38 (95.0%; P=0.047); and inhospital death in 61 (2.8%), 1 (3.5%), and no (P=0.558) patients. Clinical follow-up after a mean of 14 months showed similar rates of death, cardiac death, rehospitalization, rehospitalization for heart failure, and their composite (all P>0.05). Propensity score-adjusted analysis confirmed unadjusted analysis, with lower procedural success for the prior TEER group (odds ratio, 0.28 [95% CI, 0.09-0.81]; P=0.019) but similar odds ratios and hazard ratios for all other outcomes in the naïve, TEER, and SMVR groups (all P>0.05). CONCLUSIONS: In carefully selected patients, TEER can be performed using the MitraClip device even after prior TEER or SMVR.


Subject(s)
Cardiac Catheterization , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Mitral Valve , Registries , Humans , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/mortality , Mitral Valve Insufficiency/physiopathology , Mitral Valve Insufficiency/diagnostic imaging , Male , Female , Aged , Cardiac Catheterization/instrumentation , Cardiac Catheterization/methods , Mitral Valve/surgery , Mitral Valve/diagnostic imaging , Mitral Valve/physiopathology , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Italy/epidemiology , Aged, 80 and over , Patient Readmission/statistics & numerical data , Treatment Failure , Heart Valve Prosthesis , Mitral Valve Annuloplasty/instrumentation , Mitral Valve Annuloplasty/adverse effects , Treatment Outcome , Time Factors , Risk Factors , Heart Failure/mortality , Heart Failure/physiopathology , Heart Failure/surgery
17.
J Am Heart Assoc ; 13(10): e033601, 2024 May 21.
Article in English | MEDLINE | ID: mdl-38761069

ABSTRACT

BACKGROUND: The aims of this study were to understand the incidence and outcomes of patients with cardiogenic shock (CS) due to severe aortic stenosis (AS), and the impact of conventional treatment strategies in this population. METHODS AND RESULTS: All patients admitted to the Cleveland Clinic cardiac intensive care unit between January 1, 2010 and December 31, 2021 with CS were retrospectively identified and categorized into those with CS in the setting of severe AS versus CS without AS. The impact of various treatment strategies on mortality was further assessed. We identified 2754 patients with CS during the study period, of whom 216 patients (8%) had CS in the setting of severe AS. Medical management was associated with the highest 30-day mortality when compared with either balloon aortic valve replacement or aortic valve replacement (surgical or transcatheter aortic valve replacement) (hazard ratio, 3.69 [95% CI, 2.04-6.66]; P<0.0001). Among patients who received transcatheter therapy, 30-day mortality was significantly higher in patients who received balloon aortic valvuloplasty versus transcatheter aortic valve replacement (26% versus 4%, P=0.02). Both surgical and transcatheter aortic valve replacement had considerably lower mortality than medical management and balloon aortic valvuloplasty at 30 days and 1 year (P<0.05 for both comparisons). CONCLUSIONS: CS due to severe AS is associated with high in-hospital and 30-day mortality, worse compared with those with CS without AS. In suitable patients, urgent surgical aortic valvuloplasty or transcatheter aortic valve replacement is associated with favorable short- and long-term outcomes. Although balloon aortic valvuloplasty may be used to temporize patients with CS in the setting of severe AS, mortality is ≈50% if not followed by definitive aortic valve replacement within 90 days.


Subject(s)
Aortic Valve Stenosis , Severity of Illness Index , Shock, Cardiogenic , Transcatheter Aortic Valve Replacement , Humans , Shock, Cardiogenic/therapy , Shock, Cardiogenic/etiology , Shock, Cardiogenic/mortality , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Male , Female , Retrospective Studies , Aged , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Aged, 80 and over , Balloon Valvuloplasty/mortality , Balloon Valvuloplasty/adverse effects , Treatment Outcome , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/mortality , Risk Factors , Time Factors , Incidence
18.
Laeknabladid ; 110(5): 247-253, 2024 May.
Article in Icelandic | MEDLINE | ID: mdl-38713559

ABSTRACT

INTRODUCTION: One of the most serious complications of surgical aortic valve replacement (SAVR) is stroke that can result in increased rates of complications, morbidity and mortality postoperatively. The aim of this study was to investigate incidence, risk factors and short-term outcome in a well defined cohort of SAVR-patients. MATERIALS AND METHOD: A retrospective study on 740 consecutive aortic stenosis patients who underwent SAVR in Iceland 2002-2019. Patients with stroke were compared with non-stroke patients; including preoperative risk factors of cardiovascular disease, echocardiogram-results, rate of early postoperative complications other than stroke and 30 day mortality. RESULTS: Mean age was 71 yrs (34% females) with 57% of the patients receiving stented bioprosthesis, 31% a stentless Freestyle®-valve and 12% a mechanical valve. Mean EuroSCORE-II was 3.6, with a maximum preop-gradient of 70 mmHg and an estimated valvular area of 0.73 cm2. Thirteen (1.8%) patients were diagnosed with stroke where hemiplegia (n=9), loss of consciousness (n=3) and/or aphasia (n=4) were the most common presenting symptoms. In 70% of cases the neurological symptoms resolved or disappeared in the first weeks and months after surgery. Only one patient out of 13 died within 30-days (7.7%). Stroke-patients had significantly lower BMI than non-stroke patients, but other risk factors of cardiovascular diseases, intraoperative factors or the rate of other severe postoperative complications than stroke were similar between groups. Total length of stay was 14 days vs. 10 days median, including 2 vs. 1 days in the ICU, in the stroke and non-stroke-groups, respectively. CONCLUSIONS: The rate of stroke after SAVR was low (1.8%) and in line with other similar studies. Although a severe complication, most patients with perioperative stroke survived 30 days postoperatively and in majority of cases neurological symptoms recovered.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Stroke , Humans , Female , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/diagnostic imaging , Male , Aged , Risk Factors , Retrospective Studies , Iceland/epidemiology , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/mortality , Heart Valve Prosthesis Implantation/instrumentation , Stroke/epidemiology , Stroke/mortality , Stroke/etiology , Incidence , Time Factors , Treatment Outcome , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Risk Assessment , Aged, 80 and over , Middle Aged
19.
Tex Heart Inst J ; 51(1)2024 May 07.
Article in English | MEDLINE | ID: mdl-38711341

ABSTRACT

A 62-year-old woman who had undergone mitral valve replacement 24 years ago was admitted to the hospital with congestive heart failure. She needed heart transplantation for stage D heart failure. Preoperative cardiac computed tomographic scans showed a severely calcified left atrium and a large right atrium. Given that the left atrium's calcification was too severe to suture, the calcified left atrial wall was broadly resected, and the resected left atrial wall was reconstructed with a bovine pericardial patch for anastomosis with the donor's left atrial wall. The operation was completed without heavy bleeding, and the patient was discharged from the hospital with no complications.


Subject(s)
Calcinosis , Heart Atria , Heart Failure , Heart Transplantation , Rheumatic Heart Disease , Tomography, X-Ray Computed , Humans , Female , Rheumatic Heart Disease/surgery , Rheumatic Heart Disease/complications , Rheumatic Heart Disease/diagnosis , Heart Transplantation/methods , Middle Aged , Calcinosis/surgery , Calcinosis/diagnosis , Calcinosis/complications , Heart Atria/diagnostic imaging , Heart Atria/surgery , Heart Failure/surgery , Heart Failure/etiology , Heart Failure/diagnosis , Severity of Illness Index , Treatment Outcome , Heart Valve Prosthesis Implantation/methods , Pericardium/transplantation , Pericardium/surgery
20.
Article in English | MEDLINE | ID: mdl-38712707

ABSTRACT

In a 39-year-old male with mitral valve endocarditis, after 6 weeks of intravenous antibiotics, echocardiography confirmed multiple vegetations on both leaflets, a flail posterior leaflet flail and contained perforation of the anterior leaflet in a windsock-like morphology. All vegetations, diseased and ruptured chords and the windsock-like contained rupture of the anterior leaflet were carefully resected via a right minithoracotomy and with femoral cannulation. Three repair techniques were blended to reconstruct the valve: (1) A large, infected portion of the prolapsing posterior leaflet was resected in a triangular fashion, and the edges were re-approximated using continuous 5-0 polypropylene sutures. (2) The anterior leaflet defect was repaired with a circular autologous pericardial patch that had been soaked in glutaraldehyde. (3) A set of artificial chords for P2 was created using CV-4 polytetrafluoroethylene sutures and adjusted under repeated saline inflation. A 38-mm Edwards Physio-I annuloplasty ring was implanted. The artificial chords were adjusted again after annuloplasty and then tied. Transoesophageal echocardiography (TEE) confirmed the absence of residual mitral regurgitation and systolic anterior motion and a mean pressure gradient of 3 mmHg. The patient was discharged after 5 days with a peripherally inserted central catheter to complete an additional 4 weeks of intravenous antibiotics and had an uneventful recovery.


Subject(s)
Echocardiography, Transesophageal , Mitral Valve , Humans , Male , Adult , Mitral Valve/surgery , Mitral Valve Annuloplasty/methods , Endocarditis, Bacterial/surgery , Endocarditis, Bacterial/diagnosis , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/diagnosis , Suture Techniques , Heart Valve Prosthesis Implantation/methods , Endocarditis/surgery , Endocarditis/diagnosis , Pericardium/transplantation
SELECTION OF CITATIONS
SEARCH DETAIL
...